Generator rental

What are the effects of coolant on the operation of diesel generators

发表时间:2017-12-07 Article source : Couch motor manufacturersPublished time: 2017-12-07

There are many serious failures, often caused by slight maintenance negligence and lack of professional inspection. Diesel storage tanks can occur due to changes in water vapor in the atmosphere due to condensation at low temperatures, forming water connections to tank walls, for diesel, diesel The moisture content of the fuel exceeds the standard, and the diesel entering the engine high-pressure oil pump will rust the precision coupling plunger and cause serious damage in units. Regular maintenance can be avoided.

The diesel generator set is used as an emergency backup power supply after a power outage. Most of the time it is in standby state. Once the power outage is required, the unit is required to "up" to "get on the car." Otherwise, the backup unit will be meaningless! How did you do this ? Practice has proved that strengthening daily maintenance is a cost-effective method. As the unit is at a standstill for a long time, various chemical and physical changes in the various materials of the unit, such as oil, cooling water, diesel, and air, will cause the unit to "release" ".
During the operation of the diesel generator itself, the combustion temperature of the diesel engine will cause the surge of the diesel engine. Under the high temperature environment, it will not only affect the efficiency of the diesel generator set, but also cause component failure. Based on this, we need to cool and heat the part. Which includes the addition of coolant to the diesel cooling system.
Antifreeze action. The low temperature environment prevents the diesel engine cooling system from freezing. Generally, the commonly used coolant temperature is minus 20 degrees and the frost resistance reaches 45 degrees. It is reasonably selected according to the actual needs of different regions. Anti-boiling effect. At high temperatures, the boiling point is guaranteed. Premature boiling does not occur. Generally, the boiling point of the coolant is between 104 and 108 degrees, and it will be higher when the coolant is added to the cooling system and generates pressure.
Anti-corrosion. Special coolant can reduce the corrosion of the cooling system, avoid water leakage caused by the corrosion of the cooling system. Anti-rust effect. High-quality coolant can prevent the cooling system from rusting. Once the cooling system is rusted, it will cause accelerated wear and reduce transmission. Thermal efficiency. Anti-fouling effect. Because the coolant uses deionized water, it can prevent the formation of scale and precipitation, thereby protecting the engine.
In short, the use of the coolant and high temperature in the diesel generator cooling device solves the problem of the diesel generator set and avoids the operation failure of the diesel generator set.At the same time, its anti-corrosion, rust and anti-fouling effect is also a diesel generator set. Created work environment.

everybody is watching

  • 安装柴油发电机的注意事项
    Matters needing attention when assembling diesel generator sets: before use, it can effectively avoid unnecessary damage to the equipment, and it is easy to transfer moisture to the equipment. Attention should be paid to the assembly of the generator set and equipped with lightning protection devices. The reliability of the two-way switch wiring needs to be reviewed by the local power supply department, and the pipeline should be lowered by 5-10 degrees. If the assembly environment is wet, the generator housing must be reliably grounded and the pipe diameter must be the muffler or outlet diameter.
  • 安装柴油发电机组的方法
    The correct installation of diesel generator sets is a prerequisite to ensure safe and normal use, but many customers do not attach great importance to this aspect. This is very wrong. Diesel Generator Machinery Co., Ltd. now analyzes how to properly install diesel generator sets.
  • 柴油发电机组的换季使用注意事项
    The use and realization of diesel generators has also changed in different weather and temperatures in different seasons. So, how to make a diesel generator safely through a season in the process of using a diesel generator? Here are three suggestions. In the manual of the lubricating oil unit, there are no special requirements for oil, and there is no "winter or summer".
  • 为什么柴油发电机组需要定期保养
    The rental of diesel generators is the supplier of emergency backup power after a power failure. Most of the units are in standby mode. Once the power is cut off, it is necessary for the unit to "start in an emergency and supply power in an emergency" or the backup unit will lose its meaning. The starter battery of the unit is unprotected for a long time. The electrolyte water does not increase in real time after the water of the electrolyte evaporates. It is not equipped with a starter battery charger. The battery's power decreases after natural discharge of the battery for a long time. Charge / float charge switching. In view of the negligence of the failure to perform the switching control, the battery power cannot meet the conditions, except for handling this exception.