Handling common problems of synchronous generators

发表时间:2017-08-18 Article source : Couch motor manufacturersPublished time: 2017-08-18

Handling common problems of synchronous generators

The diesel engine is working normally, but the generator fails to generate electricity or the voltage is very low. This may be due to the components associated with the generator, such as: the exciter is damaged, and the excitation voltage cannot be supplied. The excitation current is taken in. The residual magnetism of the rotor is weakened or declining, which will make the generator unable to generate electricity or the transmission voltage is extremely low.

The right to respond usually includes: using an appropriate DC voltage and polarity, directly connected to the excitation winding to magnetize. Carefully inspect the exciter and the cyclotron rectifier, find abnormal components or windings, and replace them for restoration.

The transmission voltage of the generator is unstable, and the belt voltage is poor, and the transmission voltage drops very fiercely. Usually, the automatic voltage regulator (AVR), the excitation generator and the gyro rectifier are faulty, which is the primary cause of this phenomenon. The negative feedback transfer function of the load change is invalid, and the components of the gyro rectifier department and the components of the excitation generator voltage setting circuit are damaged.Abnormalities in that area will cause the transmission voltage to be unstable.

The actions to be adopted are: focus on surveying the AVR, and use the imitation test method to check whether its sensitivity and transmission linearity are in line with the factory standard, and if there is an abnormality, it will be repaired. There are not many components of the circuit related to the cyclotron rectifier and the excitation generator. The first is the rectifier element and potentiometer. If there is damage, change it in real time.

everybody is watching

  • 发动机应该怎么安装和连接
    The assembly place needs to be well ventilated, the generator end should have sufficient air inlets, and the diesel engine end should have excellent air outlets. The area of the air outlets should be more than 5 times larger than the area of the water tank. The periphery of the assembly site should still be clean to prevent the formation of surrounding installations. Cargoes with corrosive gases and steam such as acid, alkali, etc. Fire extinguishing devices should be equipped if required. If used indoors, the smoke exhaust pipe must be opened to the outside, the diameter of the smoke pipe must be ≥ the diameter of the smoke pipe, and the pipe connected The elbow failure should exceed 3 to ensure the exhaust smoke circulation, and the pipe should be tilted downward by 5-10 degrees to prevent rainwater intake; if the exhaust pipe is assembled vertically upward, then
  • 你知道发动机应该怎么进行保养吗
    The diesel generator set can be repaired and maintained in the middle of 6000-8000 hours. The overall control text is as follows: Check the wear level of the diesel generator set valve, the valve seat of the diesel generator set, and repair or change the diesel generator set if necessary; Check the occupational status of PT pumps and fuel injectors for leased generators, and repair and adjust if necessary. Check and adjust the torque of connecting rods and fastening screws of diesel generator sets; check and adjust the valve clearances of diesel generator sets; adjust leases The course of the injector of the generator; check the tension of the belt of the mediator fan charger; scrub the intake manifold
  • 发电机租赁期间故障怎么办
    Regarding the generator leasing problem in the use process, what should I do? This anomaly is a bit of concern for many customers who want to rent a generator. Let ’s answer it. At the beginning, as a focused generator set rental supplier The maintenance of the settings and the handling of hidden dangers in advance are real-time, thoughtful, and focused. Maybe the machine is out of the warehouse with a disease. Secondly, no supplier can promise that the settings supplied by me will not be out of order. Even new The settings are also different. For this reason, regarding the unexpected problems in the utilization process, we will send the customer to the promised hour for disposal, if necessary
  • 柴油发电机发生故障的原因及其用途有哪些
    In some places far away from the power supply, the only option is to use a diesel generator to ensure the power supply. This small-scale power generation equipment is widely used in remote areas and is of great significance to local residents. But what should I do if the diesel generator fails? What are the specific uses of diesel generators? Let ’s take a closer look at “What are the causes and uses of diesel generator failures?”